1. Before removing your Prime Chiller from the box, please note any exterior shipping damage to
the box. It is strongly recommended to keep the box and packaging material in the unlikely event
there is shipping damage or service is required.
2. Remove the chiller and controller from the box and inspect thoroughly for any signs of damage,
even if the box does not show damage. If you notice any damage (cracked or bent cover, damaged
condenser, fins, etc...) please stop and contact your dealer immediately.
3. Remove the 8 screws that hold the front cover in place and tilt the chiller up to remove the
wooden brace from underneath. The wooden brace is used to secure the motor during shipping.
Keep wooden brace with other packaging materials.
4. Make sure the chiller is placed on a firm, level surface in a location that has plenty of ventilation
and will not be exposed to salt or saltwater. Do not use an extension cord for the chiller or
the thermostat.
The requirements for ventilation are:
a) Back/Sides: Condenser (radiator) requires at least 24” clearance to allow air into the chiller.
b) Front: Requires at least 24” clearance to allow for proper air flow.
c) Chiller must not be placed in a closed closet or cabinet.
d) The warm air from the chiller must be completely evacuated from the chiller location. A fan may be
necessary to draw warm air away from the chiller. The maximum operating temperature is 95 F.
5. The drop-in cooling coil is designed to be placed below the water in a sump or tank. The coil
MUST be submersed in the water at all times to prevent damage to the coil or the chiller. Installing
the coil at a right angle will ensure a high surface area for maximum cooling.
6. The black flexible connection line MUST remain out of the water at all times. Failure to do so may
result in damage to the line. Do not kink the hose or bend to extreme angles. See Figure A.
7. Before turning on chiller, ensure the following:
a) The drop-in coil must have adequate water flow for proper operation.
Model HP Min/Max Flow
2600 1/4 9-16 gpm
2601 1/3 12-22 gpm
2602 1/4 9-16 gpm
2603 1/3 12-22 gpm
b) Make sure the pump will operate normally without any blockage.
c) Make sure the chiller is plugged into a GFCI protected 110V power outlet.
8. Set the temperature controller to the desired temperature as instructed next.